Satake Fan Performance Measuring Equipment
/Soundproof Wind Tunnel Equipment
This equipment is designed to measure the performance of discrete fans, such as sirocco fans, cross-flow fans, and propeller fans.Performance factors measured include static pressure(P), air flow(Q), and noise level.The air flow direction in the chamber can be easily changed.
Inlet air is adjustable to the predetermined setting conditions so that tests can be conducted under the same conditions at all times.The equipment automatically records the selected nozzle in addition to the measurements, processes the measured data and creates tables and charts.
1.Plenum chamber 2.Perforated plate 3.Static
pressure outlet port
4.Nozzle plate 5.Air cylinder 6.Flexible duct
7.Bypass nozzle 8.Turbo fan(for suction) 9.Turbo fan(for forced draft)
10.Rail 11.Turntable 12.Mounting base for unit
under test
●Air flow measuring range: 2 to 60 m3/min
●Static pressure range of chamber: -500 to +500 Pa
●Background noise: 20dB(A) at the ambient noise level of about 60 dB
●Sound proof chamber(anechoic chamber): Consists of two compartments; the windward compartment and the leeward compartment
|
|
|
|
|
|
 |
|
 |
|
 |
|
|
|